Embedded systems in nuclear power plant

Systematic Software Testing of Critical Embedded Digital
In our work, the testing methods were applied at the unit, module integration levels of the software of an embedded smart sensor. We provide findings on the application of this systematic testing

Verifiable Digital I&C and Embedded Digital Devices for
In the context of the electronics commodity market, embedded systems and programmable devices are dominated by products that are architected around attributes of low-power, cost, performance, configurability, and flexibility to capture wider markets.

Waste heat recovery system for nuclear power plants using the
In order to investigate the effectiveness and economic efficiency of the proposed system, a typical Japanese nuclear reactor (Kyushu Electric Power Co., Inc., Genkai Nuclear Power Plant Unit 4, a light water moderated, light water cooled, pressurized water reactor with a reactor thermal power of 3423 MWh and a rated power of 1180 MWe) was

An autonomous control framework for advanced reactors
The benefits of SMRs can include reduced financial risk, operational flexibility, and modular allocation of power production capacity. Achieving these benefits can lead to a new paradigm for plant design, construction, and management to provide for multiunit, multiproduct-stream generating stations while addressing the need to compensate for reduced economy-of

Advanced Sensors and Instrumentation Program Overview
enhance economic competitiveness for nuclear power plants, and promote a high level of nuclear safety. • NEET-ASI research produces concepts, techniques, capabilities, and equipment that are or can be demonstrated in simulated or laboratory test bed environments representative of nuclear plant systems or fuel cycle systems.

Technical Meeting on the Software Reliability of Digital
The event will address recent experiences in Member States to overcome difficulties as well as to promote solutions affecting the reliability of the software embedded in digital I&C systems for

Practice Test: Module 05 Mobile, Embedded, and Specialized
Study with Quizlet and memorize flashcards containing terms like John works in a nuclear power plant. He discovered a worm that was actively targeting Windows computers that manage large-scale SCADA systems. The malware attempted to gain administrative access to other computers through the network to control the SCADA system. Which of the following malware can do all

Making ''digital twins'' to monitor and control tomorrow''s reactor
Now researchers at Idaho National Laboratory are taking embedded smart systems one step further with the development of so-called "digital twins" – essentially virtual replicas of nuclear reactors. supervision and security. "Advanced nuclear reactors need to have these systems to have the functionalities to compete in the

Office Of Nuclear Energy Sensors and Instrumentation
All nuclear power plant classes require coolant pumps • Highly relevant demonstration in a representative environment Pump seals and bearings are maintenance intensive • Pump seals and bearings are have been historic source of problems in nuclear power applications • Helium circulator seal leaks were a significant source of problems at Fort

A Pseudo Exhaustive Software Testing Framework for
for the instrumentation and controls (I&C) operations in Nuclear Power plants. Of specific interest is the use of advanced software-based embedded digital devices (EDDs) that have the potential to substantially increase plant reliability and performance operations. EDDs are typically edge devices like sensors, transmitters and actuators.

Systematic Software Testing of Critical Embedded Digital
nuclear industry for addressing vulnerabilities associated with SCCFs [1]. However, the disadvantages of large scale diversity methods for plant modernization are significant implementation costs, and increased plant integration complexity. Consequently, there has been much interest within the nuclear industry in the past 10 years toward

Thin-Plate-Type Embedded Ultrasonic Transducer Based on
1. Introduction. Wall thinning of a secondary piping system is a critical issue related to the safety of nuclear power plants (NPPs). This condition can even lead to fatalities when, for instance, the main feed-water pump has an elbow rupture, as occurred in the Surry Unit 2 in the USA or when the condensate system has a straight pipe rupture, such as in Mihama Unit 3 in

Instrumentation and Control Systems of Nuclear Power Plants
NUREG/CR-7007, published in 2008 as ''''Diversity Strategies for Nuclear Power Plant Instrumentation and Control Systems," provided guidance to determine how much diversity in a safety system is

Nuclear Power Plants With Artificial Intelligence in Industry 4.0
As a typical and complex man-machine-network integration system, various faults, insufficient automation and stressed human operators limit the further popularization of nuclear power plants (NPPs

NRC REGULATORY ISSUE SUMMARY 2013
the need to identify, review, document, and control embedded digital devices in safety systems, in order to comply with 10 CFR 50.55a(h), "Protection and Safety Systems;" Appendix A, "General Design Criteria for Nuclear Power Plants;" and Appendix B, "Quality Assurance Criteria for Nuclear Power Plants and Fuel Reprocessing Plants."

James A. FitzPatrick Nuclear Power Plant
The James A. FitzPatrick (JAF) Nuclear Power Plant is located in the Town of Scriba, near Oswego, New York, on the southeast shore of Lake Ontario.The nuclear power plant has one General Electric boiling water reactor.The 900-acre (360 ha) site is also the location of two other units at the Nine Mile Point Nuclear Generating Station.. The power plant was originally built

Application of Continuous Integration in the Development of Embedded
With high reliability requirements, the nuclear grade paperless recorder, as the main equipment for monitoring, displaying and recording the operating parameters of nuclear power plants, is a typical embedded software operation equipment, have the characteristics of multiple software modules and multi-team development.

Thin-Plate-Type Embedded Ultrasonic Transducer Based on
DOI: 10.1016/J .2016.05.007 Corpus ID: 113978768; Thin-Plate-Type Embedded Ultrasonic Transducer Based on Magnetostriction for the Thickness Monitoring of the Secondary Piping System of a Nuclear Power Plant

Verifiable Digital I&C and Embedded Digital Devices for
Since the 1970s when most nuclear power plants (NPPs) were built, dramatic advances in electronics, communications, networking, and embedded systems and programmable devices are dominated by products that are architected around attributes of low-power, cost, performance, con!gurability,

REGULATORY REQUIREMENTS, GUIDANCE, AND REVIEW OF EMBEDDED
Interest in embedded digital devices (EDDs) for monitoring and providing control of components is increasing in the nuclear power market as more and more users both within and outside the nuclear sector are employing EDDs. EDDs in other industries or countries may be known by the related terms as smart devices, devices of limited functionality, or intelligent

Instrumentation and control systems design for nuclear power plant
Instrumentation and Control systems (I&C) play a significant role in nuclear power plants (NPP) and other safety critical systems (SCS). We have conducted a rigorous study and discussions with experienced practitioners worldwide the strategy for the development of I&C systems to investigate the several aspects related to their dependability.

Nuclear Power Plant Safety Systems
Each nuclear power plant in Canada has multiple, robust safety systems designed to prevent accidents, and reduce its effects should one occur. All of these systems are maintained and inspected regularly, and upgraded when necessary, to ensure plants meet or exceed strict safety standards established by the Canadian Nuclear Safety Commission.

Embedded System on Safety Critical For Nuclear Power Plant
Safety-critical systems are embedded systems that could cause injury or loss of human life if they fail or encounter errors. Flight-control systems, automotive drive-by-wire, nuclear reactor management, or operating room heart/lung bypass machines naturally come to mind. Small system defects or situations can cascade into life-threatening failures very quickly.A low-level

Reliability Analysis of Instrumentation and Control System: A
Instrumentation and control system (I&Cs) plays a key role in nuclear power plants (NPP) whose failure may cause the major issue in a form of accidents, hazardous radiations, and environmental loss. That is why importantly ensure the reliability of such system in NPP. In this proposed method, we effectively analyze the reliability of the instrumentation and control system.

Design and Implementation of Embedded System for Nuclear
This paper tries to solve that challenge by design and implement of an embedded system for nuclear materials cask. This system is suitable to developing countries, where it is cost effective and it uses the existing infrastructure. Recent advancements in nuclear fission technology have led to predict that the number of Nuclear Power

Technical Meeting on the Software Reliability of Digital
Digital Instrumentation and Control Systems for Nuclear Power Plant Safety incorporate an embedded software code or algorithm or even a computer-based software. In many NPPs, programmable digital I&C systems are interconnected and more complex to analyse (and, thus, safety assurance is more difficult to demonstrate than was the case for

6 FAQs about [Embedded systems in nuclear power plant]
Should nuclear power plants adopt digital safety systems?
Despite these benefits, adoption of digital I&C systems for safety-related applications across the domestic nuclear fleet has been slow. U.S. nuclear power plants that do choose to embrace the transition from analog to digital are in good company; international plants have successfully implemented digital safety systems for more than a decade.
How can digital I&C improve nuclear power plants?
By implementing digital I&C technology, nuclear power plants can improve system reliability and streamline operations while lowering maintenance costs and supporting industry modernization and plant life extension initiatives. Simply put, digital I&C can enable the transformation and modernization of plant operations.
What is digital I&C in nuclear power plants?
The analogue I&C, initially installed on operating nuclear power plants have been gradually replaced by digital I&C systems to provide control and protection functions. In addition, digital I&C is commonly used in all new nuclear power plant designs.
How reliable are digital instrumentation and control systems for nuclear power plants?
Technical Meeting on the Software Reliability of Digital Instrumentation and Control Systems for Nuclear Power Plant Safety Instrumentation and control systems (I&C) are a key element for the safe design, operation and management of nuclear power plants during all plant states.
What is safety-related I&C design for existing nuclear power plants?
Safety-related I&C design for existing nuclear power plants is complex. The plants’ non-passive designs require numerous redundant safety systems, equipment, and operating procedures; all incorporated into the plant’s design basis. As a result, upgrading an existing plant’s I&C systems is complex, time-consuming, and expensive.
Can safety instrumentation & control transform nuclear plant operations?
As the U.S. nuclear industry moves into plant life extension and subsequent license renewals, the modernization of safety instrumentation and control (I&C) systems holds significant potential to transform plant operations.
Related Contents
- Thermodynamics in nuclear power plant systems
- Embedded systems low power architecture arm
- Embedded systems applications in power electronics
- Embedded systems power management
- Concentrated solar power plant systems
- Wallis and Futuna nuclear power plant battery
- Power management in embedded system
- Solar powered embedded systems
- Louisiana power systems
- Efficient electric power systems
- Penske power systems perth
- Thomson power systems transfer switch